<LOGO>
FM Transmitter Measurement Report
Created: 2025-10-20 09-44-50
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 56 dBuV SANDELS
Pilot RDS Phase Difference
6.0 kHz 5.2 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
11 kHz 69 kHz 10878 3,2451
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
3,8 dBr 5,39 dBr 6,4 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
92.0, 94.7, 106.4, 107.5 MHz -
FM Scope Max at: 69 kHz MIN: 11 kHz % above 76 kHz: 3,2451 Acquired: 2025/10/20 9.43.46 Total samples: 10878 Equivalent time: 0:09:03 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 6,4 dBr MIN: 3,8 dBr AVE: 5,39 dBr % above 12,2 dBr: 0,0 Last value: 6,3 dBr (2025/10/20 9.43.46) 09.30 09.32 09.34 09.36 09.38 09.40 09.42 0 2 4 6 Pm [dBr]